OLDS ELEVATOR: IMPRESSIVE HEAT EXCHANGER FOR HOT SAND

Olds elevator used as a heat exchanger for foundry sand shows impressive performance.

Hudson, New Hampshire (March 4, 2010) - Olds Elevator LLC of Hudson, NH and Palmer Mfg. and Supply Co. of Springfield OH collaborated on a series of trials using an Olds elevator as a heat exchanger for hot foundry sand by running tap water through the hollow shaft of the Olds elevator's static screw. During normal elevation of hot sand, heat is extracted through the screw by running a stream of low-flow (2 gpm) tap water through the screw shaft.

The elevator/heat exchanger was tested under a range of conditions of sand flow, sand temperature and water flow rates.

Refer to photo of test equipment configuration. A description of the equipment setup is: Left to right:

Olds elevator: 12 foot tall, 5.875 inch ID rotating casing, 5.25" OD static screw with 1.25" hollow shaft. Screw flighting continuously welded to shaft top and bottom. Water line feeds tap water into bottom of screw shaft. Flow is regulated by a valve with in-line flow meter... Elevator controlled with VFD to allow regulation of sand flow rate to a maximum of 5.58 tons/hour

Sand Heater: Electrically heated elements in fluidized bed by compressed air supply. Sand supplied from Olds elevator discharge. Heated sand fed directly to Olds elevator feed hopper.

Sand Heater Controls: Air flow and temperature controls

Examples of the effectiveness of the elevator/heat exchanger at different flow rates:

Sand
Flow
lb/min
Water
Flow
GPM
Water
Temp In
T°F
Sand
Temp In
T°F
Sand
Temp Out
T°F
Water
Temp Out
T°F
% Heat
Reduction
Sand
63 2 47 187.5 140.2 61 25.4
96 2 47 189.5 146.0 63 22.9

Additional testing is scheduled using hollow flighted screws, in addition to hollow shafted screws, which will triple the surface area of the chilled screw surface in contact with the moving sand.

The Olds/Palmer elevator/heat exchanger will be demonstrated at the upcoming CAST EXPO 2010 in Orlando, FL from March 20-23. The CAST EXPO serves the nations foundry industry.

For more information contact: sales@oldsusa.com
Web Site: www.oldsusa.com
Engineering and Support

Free Video Taped Test
Materials Handled
Performance Features
Standard Configurations
Test Laboratory


OLDS ELEVATOR™ LLC
12 B Park Ave.
Hudson, NH 03051

Call 603.882.8899
Fax 603.882.8855



OLDS ELEVATOR™
Advantages

1. Olds Elevator Innovative
Material Elevation
  • No Segregation
  • No Breakage
  • No DustMore…
Bulk Material Handling Systems | Dense Abrasives | Dust Control | Dust Explosion Prevention | Free Video Taped Test | Gentle Handling Dust-Free Elevation
Materials Handled | Mobile Units | Pneumatics versus Olds Elevators | Performance Features | Standard Configurations
Test Laboratory | Vertical Elevation | Volumetric Feeders | OLDS ELEVATOR™ Site Map


Hudson, NH Website Design Development

Dissatisfied by conventional methods with bucket elevators, screw elevators, pneumatic conveyors and inclined belt conveyors? OLDS ELEVATOR™ has
developed a radical concept that overcomes all the obstacles of elevating while providing engineering design, elevator manufacturing, installation and service.
MA, Massachusetts, NH, New Hampshire, CT, Connecticut, RI, Rhode Island, VT, Vermont, ME, Maine, New England and all of the United States and Canada